Consult an expert
ENERGY LINE GENSETMade in Germany

Stop paying more for diesel.Switch to gas.

Discover Energy Line – a cost-effective alternative to diesel power, designed for reliable performance and long-term savings.

  • Up to 79%

    Lower fuel costs per kWh

  • 5 fuel options

    Natural gas · CNG · LNG · LPG · Flare gas

  • 1 day

    Commissioning time

  • Made in Germany

    Reliable engineering, proven quality

The product

Energy Line Genset. German-engineered gas power, simplified.

Designed for industrial and commercial applications, Energy Line provides a reliable, cost-effective solution for continuous, backup and peak power generation. Easy to install and operate, it delivers dependable performance even in demanding conditions.

  • 400–⁠500 kW / 500–⁠625 kVA

    Power output

  • Up to 41%

    Electrical efficiency

  • +45°C

    Hot-climate operation without derating

  • Outdoor-ready

    Weatherproof enclosure

  • Factory-tested

    Before shipment

Energy Line Genset without enclosure: gas engine, single-bearing alternator, radiator and exhaust silencer on one frame
Energy Line Genset in its outdoor weather enclosure with exhaust silencer
Under the panels: gas engine, single-bearing alternator, radiator and exhaust silencer factory-mounted on one frame.

Diesel vs Energy Line

The generator is not the cost. The fuel is.

A diesel set is cheaper to buy and more expensive every hour after that. Here is what actually differs over a ten-year life.

ComparedDiesel gensetEnergy Line Genset
FuelBought by the litre, trucked, stored, measured against theft and adulterationPipeline gas, trucked CNG, LPG, or associated gas already on your site
Electrical efficiencyTypically 33–37% at full load, falling at part load39.9% COP, 40.5% PRP, 41.0% ESP – stable at partial load
Oil serviceCommonly 250–500 operating hours700 operating hours
Emissions and neighboursParticulates, smoke, fuel odour on siteCleaner combustion; oxidation catalyst available for compliance
CO₂ emissionsHigher CO₂ emissions from fuel combustionNatural gas emits ~30% less CO₂ per unit of fuel energy
End of lifeReplaced when wornOverhaul-oriented design – no fixed end of life

Diesel figures are typical industry ranges for comparison, not measurements of a specific competing unit. Energy Line figures are from the product specification.

Lower CAPEX through reduced complexity

Simpler engineering. Proven reliability. Lower entry price.

Energy Line removes unnecessary system complexity while retaining the core engineering and reliability that matter in daily operation.

Standalone operating concept

  • Reduced electrical system complexity
  • Lower commissioning effort
  • Optimized for autonomous power supply

Single-bearing alternator design

  • Reduced component count
  • No clutch assembly required
  • Simplified drivetrain integration

Standardized configuration platform

  • Outdoor enclosure
  • Enhanced cooling system
  • Oxidation catalyst option

700-hour oil service interval

  • Simplified maintenance strategy
  • Reduced oil system size
  • Service concept matched to local operating conditions

Platform unification approach

  • Reduced layout variability
  • Simplified production engineering
  • Faster assembly and delivery cycles

Less complexity. Lower CAPEX and OPEX. German quality.

A focused, standardized design reduces component count, integration effort and production complexity while retaining proven reliability – lower CAPEX at purchase, lower OPEX on gas fuel and a 700-hour oil service interval. Designed and manufactured in Germany.

Technical specifications

The numbers

Power output
400–500 kW
Power ratings
COP (Continuous) 400 kWPRP (Prime) 450 kWESP (Maximum) 500 kW
Electrical efficiency
39.9% (COP)40.5% (PRP)41.0% (ESP)
Operating concept
Standalone / island operationother modes optionally available
Oil change interval
700 operating hours
Warranty
12 months standard

Fast deployment & simplified service

On site in a day, serviceable for decades

Plug-and-play installation

  • Factory-tested before shipment
  • Reduced commissioning complexity
  • Standardized platform architecture
  • Faster site energization
  • Minimal on-site integration work

Commissioning
within 1 day

No fixed
end of life

Overhaul-oriented lifecycle design – the unit is rebuilt, not retired.

Simplified service concept

  • Lightweight aluminium access panels for single-person servicing
  • Reduced component variability
  • Standardized spare parts approach
  • Simplified maintenance procedures
  • Overhaul-oriented lifecycle design

Competitive positioning

Where Energy Line sits between the extremes

Premium European manufacturers

Focus on high-complexity premium systems with significantly higher CAPEX and extensive customization.

Energy Line Genset

Proven German quality at close to low-cost market pricing.

  • Up to 50% below comparable German gensets
  • Designed and manufactured in Germany
  • Proven German engine and engineering
  • Plug-and-play standalone operation
  • Factory-tested before shipment
  • Built for overhaul and long-term operation
  • Manufacturer service and 24/7 technical support

Low-cost market alternatives

Prioritize minimum upfront cost, often with reduced lifecycle capability, limited overhaul ability, variable deployment quality and thin after-sales service once the unit is on site.

Made in Germany

We develop and manufacture our products at our own facility in Mendig, Germany. From engine components and steel fabrication to CNC machining and control systems, we manage key production processes in-house to ensure consistent quality and reliability.

  • 50+years

    of engineering experience

  • 40+countries

    worldwide presence

  • ISO 9001

    certified quality management

R Schmitt Enertec production site in Mendig, Germany, at dusk

Our Projects

Real-world applications of Enertec power solutions across industries and countries.

  • Adare Manor Hotel & Golf Resort, Ireland

    AdareIreland

    Containerised CHP solution delivering reliable energy for a luxury hotel and golf resort while minimizing space requirements.

  • Scholzehof biogas plant, Germany

    ScholzehofGermany

    High-efficiency biogas utilisation for electricity generation and district heating supported by an advanced gas cleaning system.

  • Monheim wastewater treatment plant, Germany

    MonheimGermany

    On-site generation of power and heat from sewage gas, supporting wastewater treatment processes with maximum energy efficiency.

  • Gas engine plant at the NIS oil fields near Novi Sad, Serbia

    Novi SadSerbia

    On-site generation of power and heat from associated gas, turning a flared by-product into usable energy at the wellhead.

Cost check

What gas would cost you against diesel

Use your own delivered prices – the figures update as you type.

Energy Line Genset

COP · continuous · 400 kW installed · 39.9% electrical efficiency

Electricity per year
2,400 MWh
Gas consumption
633,162 Sm³/yr
Annual gas bill
₦279.2 m
Same output on diesel
₦1.33 bn

Indicative fuel cost avoided per year

₦1.05 bn

Send this to an engineer

Prefilled with current Nigerian prices: diesel ₦1,900 per litre and gas US$8.92 per Mscf – about ₦441 per Sm³ at $1 = ₦1,400. Indicative only. Assumes 9.5 kWh per Sm³ of natural gas at the stated electrical efficiency, and a diesel genset at 35% efficiency on 9.8 kWh per litre. Real figures depend on gas composition, load profile and site conditions – we confirm them in the offer.

Consult an expert

Tell us about your site

Send the load, the gas you have access to and the hours you run. An engineer comes back with a configuration, expected gas consumption and a budget price.

  1. 01step

    You send the basics

    Load, fuel, operating hours, location.

  2. 02step

    We size the plant

    Rating, configuration and layout, usually within two working days.

  3. 03step

    You get a budget offer

    Equipment, options, delivery to Lagos or Port Harcourt, commissioning and service scope.

= required

Your details are used only to process your request. By submitting this form, you confirm that you have read and agree to our Privacy Policy.

Consult an expert